| Order number including voltage version | 9600063.03 |
|---|---|
| Working temperature range | -10 ... +80 °C |
| Temperature stability | ±0.2 °C |
| Heating capacity | 1.2 kW |
| Pump capacity flow rate | 22 l/min |
| Pump capacity pressure | 1.2 bar |
| Filling volume | 6 ... 8 l |
|
Total dimensions
(W × L × H) |
36 x 54 x 49 cm |
Product Features
- Adjustable ratio for feed/return temperatures
- Easy filling system located at the front
- Activation of pump for filling
- Bright MULTI-DISPLAY (LED)
- Upper and lower temperature warning functions with interval tone
- Integrated freezing protection and dry-running protection
- Rapid and easy operation via seamless, splash-proof keypad
- Liquid level indication on the front
- Self-test, reciprocal sensor monitoring, pump motor and compressor overload protection
- Complete shut-down with audible signal in case of an alarm
- removable venting grid for simplified removal of dust
- RS232 interface for PC connection
- High temperature stability
- Integrated heater with 1.2 kW capacity
Technical data for FC600S
|
Total dimensions (W × L × H) |
36 x 54 x 49 cm |
|---|---|
| Filling volume | 6 ... 8 l |
| Weight | 44 kg |
| Pump connections | M16x1 male |
| Barbed fittings inner diameter | 8/12 mm |
| Working temperature range | -10 ... +80 °C |
|---|---|
| Temperature stability | ±0.2 °C |
| Temperature display resolution | 0.1 °C |
| Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
| Heating capacity | 1.2 kW | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
| Pump capacity flow rate | 22 l/min | |||||||||||||||||||||
| Pump capacity pressure | 1.2 bar | |||||||||||||||||||||
| Power consumption | 8 A | |||||||||||||||||||||
| Bath tank | Stainless steel |
|---|
| Cooling of compressor | 1-stage Air |
|---|
| Sound pressure level | 54 dB(A) |
|---|---|
| Classification according to DIN12876-1 |
Classification III (FL) |
| IP Code according to IEC 60529 |
IP 21 |
| Pump type | Immersion Pump |
| Interfaces | Alarm output / Profibus optional / RS232 / Stakei / Standby-Input |
|---|---|
| External pt100 sensor connection | not available |
| Temperature control | PID1 |
| Temperature display | 2x LED |
| Temperature setting | Keypad |
| 9600063.13 | 230V 60Hz (Nema N6-20 Plug) (R134a) |
|---|---|
| 9600063.03 | 230V 50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
| 9600063.04 | 230V 50Hz (UK Plug Type BS1363A) (R134a) |
| 9600063.05 | 230V 50Hz (CH Plug Type SEV 1011) (R134a) |
| 2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for FC600S
Downloads for FC600S
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFC600S Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
For flammable bath fluid
Classification III (FL) according to DIN 12876-1