PRESTO W56x Process system
The most powerful, single-stage, highly dynamic temperature control systems
The water-cooled PRESTO W56x is able to quickly and efficiently control the temperature in applications requiring a great deal of power. Even at low temperatures, this model has large power reserves for demanding external applications.
The PRESTO W56x process system is equipped with a gear pump. As a result, bath fluids with a high viscosity, such as water-glycol mixtures at low temperatures of up to -45 °C, can also be used .
The magnetically coupled pump allows the user to optimally adjust pump capacity to suit the application, even over large distances and height differences, as well as for pressure-sensitive applications. Use of the latest thermodynamic technologies means that the cooling capacity is automatically adjusted to the current power requirements. Combined with further optimizations, the PRESTO W56 is both incredibly economical and energy-efficient.
Water-glycol up to +150 °C
Connection of an expansion kit ( accessorie) allows pressurized temperature control with water-glycol up to a working temperature of +150 °C.
Order No. | 9421563.S1.17 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -50 ... +250 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature stability | ±0.05 ... ±0.1 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Heating capacity | 27 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 0 ... 70 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Circulation capacity pressure | 1.5 ... 79.8 psi | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions
(W × L × H) |
23.6 x 37 x 64.6 in. |
Product Features
- External Pt100 sensor connection
- Analog connections, RS485, Profibus DP (accessory)
- Second external Pt100 sensor connection (accessory)
- Heating capacity up to 27 kW
- Temperature stability ±0.05 °C ... ±0.1 °C
- Alarm output
- Built-in 5.7’’ industrial color touchscreen
- Cooling capacity up to 25 kW
- Pump pressure up to 5.5 bar, max. flow rate 70 l/min
Technical data for PRESTO W56x
Dimensions (W × L × H) |
23.6 x 37 x 64.6 in. |
---|---|
Internal usable expansion volume | 17.5 l |
Minimal process volume | 11 l |
Active heat exchanger volume | 10 l |
Weight | 848.8 lbs |
Pump connections | M38x1.5 male |
Cooling Water Connection | G¾ in. |
Working temperature range | -50 ... +250 °C |
---|---|
Temperature stability | ±0.05 ... ±0.1 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 27 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 0 ... 70 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Circulation capacity pressure | 1.5 ... 79.8 psi | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Viscosity max. | 280 cSt | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption | 47 A |
Cooling of compressor | 1-stage Water |
---|---|
Cooling water pressure max. | 87 psi |
Max. heat dissipated by unit into cooling water | 44 kW |
to provide full cooling capacity according to catalog values | |
Cooling water temperature range | 10 ... 15 °C |
---|---|
Cooling water difference pressure | 21.8 ... 87 psi |
Cooling water consumption 2 | 14 ... 25 l/min |
2 Cooling water consumption may vary outside recommended cooling water properties. |
Cooling water temperature range | 5 ... 35 °C |
---|---|
Cooling water difference pressure 3 | 7.3 ... 87 psi |
3 At cooling water temperatures of 25 °C and higher, the minimum differential pressure is 1 bar. |
Sound pressure level | 72 dbA |
---|---|
Classification according to DIN12876-1 |
Classification III (FL) |
IP Code according to IEC 60529 |
IP 20 |
Pump type | Gear Pump |
Interfaces | Alarm output / Ethernet / Modbus / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB |
---|---|
External pt100 sensor connection | integrated |
2nd external Pt100 sensor connection | accessory |
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | 5.7" TFT Touchscreen |
Temperature setting | Touchscreen |
9421563.S1.07 | 400V/3PNPE/50Hz (Plug 63A CEE) (R449A) |
---|---|
9421563.S1.17 | 480V/3P(N)PE/60Hz (Without Plug) (R449A) |
Accessory for PRESTO W56x
Downloads for PRESTO W56x
We would also be happy to send you our printed catalogs and brochures by post.
Request brochurePRESTO W56x Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
Convenience for several users
Administrator level for customizing instrument settings, user levels with limited permissions for fast and safe defined access, password protection, all levels adjustable
Related Products
Products with similar properties